Darmowa dostawa z usługą Inpost oraz Orlen od 299.00 zł
InPost 13.99 Poczta Polska 18.99 Paczkomat 13.99 DPD 25.99 ORLEN Paczka 10.99

Microautoradiography and Electron Probe Analysis

Język AngielskiAngielski
Książka Miękka
Książka Microautoradiography and Electron Probe Analysis U. Lüttge
Kod Libristo: 06805498
In biological literature, several definitions of quantitative autoradio graphy are given. The term i... Cały opis
? points 304 b
517.77
Dostępna u dostawcy w małych ilościach Wysyłamy za 13-16 dni
Polska common.delivery_to

30 dni na zwrot towaru


Mogłoby Cię także zainteresować


Just Right Teacher's Book Jeremy Harmer / Miękka
common.buy 66.61
Medication Diary Sheron Pharm D Zellous / Twarda
common.buy 148.84
De la Terre ? la Lune Jules Verne / Miękka
common.buy 66.51
Magic Mirror Ed Pinsent / Twarda
common.buy 152.94
Mephistowalzer Sergio Pitol / Twarda
common.buy 93.72
Madison County Linda J. Higgins / Twarda
common.buy 113.53
Mathe an Stationen, Klasse 5 Gymnasium Tanja Zimmermann / Karta
common.buy 100.22
From My Heart Cindy Young / Miękka
common.buy 151.04

In biological literature, several definitions of quantitative autoradio graphy are given. The term is defined as either the determination and com parison of the density of silver grains above various structures or under varying conditions, or the determination of absolute quantities of radio activity. In both these cases, photometric measurement serves for more rapid and more exact evaluation of grain densities than would be possible by visual counting of the grains. The equipment generally used for the photometric measurement of silver grains consists of a microscope, a photocell, an electronic amplifier system and a display unit. Grains can be made accessible to photometric evaluation by various kinds of microscopic illumination: 1. Substage bright-field illumination. 2. Substage dark-field illumination. 3. Incident dark-field illumination. 4. Vertical bright-field illumination. With all these types of illumination, the relationship between the luminous flux I absorbed by the film, scattered into the objective and reflected or diffracted, and the flux 10 which is not affected by the film is used as a measure of grain density. Since these are differential measurements, the light beam I transmitted by the film is in itself a measure of grain density if the luminous flux 10 incident on the grains is kept constant. This approach has been used in a large number of measuring setups.

Informacje o książce

Pełna nazwa Microautoradiography and Electron Probe Analysis
Autor U. Lüttge
Język Angielski
Oprawa Książka - Miękka
Data wydania 2012
Liczba stron 242
EAN 9783540059509
ISBN 3540059504
Kod Libristo 06805498
Waga 500
Wymiary 155 x 235 x 14
Podaruj tę książkę jeszcze dziś
To łatwe
1 Dodaj książkę do koszyka i wybierz „dostarczyć jako prezent” 2 W odpowiedzi wyślemy Ci bon 3 Książka dotrze na adres obdarowanego

Logowanie

Zaloguj się do swojego konta. Nie masz jeszcze konta Libristo? Utwórz je teraz!

 
obowiązkowe
obowiązkowe

Nie masz konta? Zyskaj korzyści konta Libristo!

Dzięki kontu Libristo będziesz mieć wszystko pod kontrolą.

Utwórz konto Libristo