Darmowa dostawa z usługą Inpost oraz Orlen od 299.00 zł
InPost 13.99 Poczta Polska 18.99 Paczkomat 13.99 DPD 25.99 ORLEN Paczka 10.99

Control of a Wind Driven Doubly Fed Induction Generator During Grid Faults

Język AngielskiAngielski
Książka Miękka
Książka Control of a Wind Driven Doubly Fed Induction Generator During Grid Faults Mahmoud Mossa
Kod Libristo: 05283714
Wydawnictwo Grin Publishing, luty 2013
Master's Thesis from the year 2013 in the subject Engineering - Power Engineering, grade: none, - (F... Cały opis
? points 201 b
341.81
Dostępna u dostawcy Wysyłamy za 15-20 dni
Polska common.delivery_to

30 dni na zwrot towaru


Mogłoby Cię także zainteresować


Auxology Michael Hermanussen / Twarda
common.buy 152.24
Creative Haven WinterScapes Coloring Book Jessica Mazurkiewicz / Miękka
common.buy 29.50
Zapowiedź
Clinical Infertility and In Vitro Fertilization Botros R. M. B. Rizk / Twarda
common.buy 1 045.85
American Theater in the Culture of the Cold War Bruce A. McConachie / Twarda
common.buy 257.78
Tragverhalten von Stahl-Glas-Verbundkonstruktionen Georg Terfloth / Miękka
common.buy 1 042.44
Circuitous Journeys David J. Leigh / Twarda
common.buy 368.22
Bridging the Border Rodolfo O. De la Garza / Miękka
common.buy 271.88
Amulet Manual Kim Farnell / Miękka
common.buy 64.21
Der dritte Mann im Ring Arthur Mercante / Twarda
common.buy 130.54
Better Woman Ber Carroll / Miękka
common.buy 150.14
Binnen der rothen Tonne Heinrich Smidt / Miękka
common.buy 127.13
Hammurabi's Laws MEJ Richardson / Miękka
common.buy 573.29
Armenian Question in the Caucasus Tale Heydarov / Twarda
common.buy 385.22
... und fahr'n wir ohne Wiederkehr Fritz Blankenhorn / Miękka
common.buy 41.60

Master's Thesis from the year 2013 in the subject Engineering - Power Engineering, grade: none, - (Faculty of engineering-Minia university - Electrical engineering department), course: Electrical engineering (Renewable energy), language: English, abstract: Wind electrical power systems are recently getting lot of attention, becausethey are cost competitive, environmental clean and safe renewable powersource, as compared with fossil fuel and nuclear power generation. A specialtype of induction generator, called a doubly fed induction generator (DFIG),is used extensively for high-power wind applications. They are used moreand more in wind turbine applications due to ease controllability, highenergy efficiency and improved power quality.This thesis aims to develop a method of a field orientation scheme forcontrol both the active and reactive powers of a DFIG driven by a windturbine.The proposed control system consists of a wind turbine that drives aDFIG connected to the utility grid through AC-DC-AC link. The maincontrol objective is to regulate the dc link voltage for operation at maximumavailable wind power.This is achieved by controlling the and axescomponents of voltages and currents for both rotor side and line sideconverters using PI controllers. The complete dynamic model of theproposed system is described in detail. Computer simulations have beencarried out in order to validate the effectiveness of the proposed systemduring the variation of wind speed. The results prove that , better overallperformances are achieved, quick recover from wind speed disturbances inaddition to good tracking ability.Generally, any abnormalities associated with grid asymmetrical faults aregoing to affect the system performance considerably. During grid faults,unbalanced currents cause negative effects like overheating problems andmechanical stress due to high torque pulsations that can damage the rotor shaft, gearbox or blade assembly. Therefore, the dynamic model of theDFIG, driven by a wind turbine during grid faults has been analyzed anddeveloped using the method of symmetrical components. The dynamicperformance of the DFIG during unbalanced grid conditions is analyzed anddescribed in detail using digital simulations.A novel fault ride-through (FRT) capability is proposed (i.e. the ability ofthe power system to remain connected to the grid during faults) with suitablecontrol strategy in this thesis. In this scheme, the input mechanical energy ofthe wind turbine during grid faults is stored and utilized at the moment offault clearance, instead of being dissipated in the resistors of the crowbarcircuit as in the existing FRT schemes. [...]

Informacje o książce

Pełna nazwa Control of a Wind Driven Doubly Fed Induction Generator During Grid Faults
Język Angielski
Oprawa Książka - Miękka
Data wydania 2013
Liczba stron 140
EAN 9783656368380
ISBN 3656368384
Kod Libristo 05283714
Wydawnictwo Grin Publishing
Waga 191
Wymiary 148 x 210 x 8
Podaruj tę książkę jeszcze dziś
To łatwe
1 Dodaj książkę do koszyka i wybierz „dostarczyć jako prezent” 2 W odpowiedzi wyślemy Ci bon 3 Książka dotrze na adres obdarowanego

Logowanie

Zaloguj się do swojego konta. Nie masz jeszcze konta Libristo? Utwórz je teraz!

 
obowiązkowe
obowiązkowe

Nie masz konta? Zyskaj korzyści konta Libristo!

Dzięki kontu Libristo będziesz mieć wszystko pod kontrolą.

Utwórz konto Libristo